FLOW METER OVAL FLOWPET-NX LS5576- 2OO A

Rp. 900
Last Updated
25 Sep 2023
Country Origin
Indonesia
Minimum Order
1 Unit
FLOW METER OVAL FLOWPET-NX LS5576-2OOA

General Specifications



Flow Range



Model
:
LS5576-2OOA

Nominal Size (mm)
:
40

Flange Rating
:
JIS 10K RF

Flow Range , L/h



Kerosene
:
1200 to 11000

(Above 0.8mPa•s to 2mPa•s)



Gas Oil (Heavy oil A)
:
600 to 14000

(Above 2mPa•s to 5mPa•s)



Heavy Oil
:
400 to 14000

(Above 5mPa•s to 200mPa•s)







Meter Body



Acceptable flulds
:
Kerosene,Light oil,Heavy Oil (Not serviceable with gasoline)

Operating temp . Range (fluid temp.)
:
0 to 120⁰C

Max.operating pressure
:
1.18MPa

Linearity
:
±0.35% of RD

Material



Body
:
FC250

Rotors
:
Special resin

Flow direction
:
Right → Left (standard),Left → right,bottom → top,top → bottom

Coating color
:
Orange : Munsell 2.5 YR 6/13





Mechanical Register Specifications



Model
:
LS5576

Functions
:
Cumulative counter with dial-and-pointer,6 digits number wheels

Display



One pointer rev
:
10 L

Resolution
:
0.1L

Counter capacity
:
9,999,999.9L

Output Pulse
:
See next section

Operating Temp Range
:
-10 to +60⁰C

Construction
:
Waterproof conforming to IP 65 (weathertight)

Material
:
Resin/Alumunium die casting

Finish (houshing)
:
Munsell 4.9 PB4.0/13.9 (Color of molding)





Factored Pulse generator in Mechanical Register (optional)

Item
:
MR sensor

Type of output pulse
:
Voltage pulse/open collector

Number of pulses (per pointer rev.)
:
10 P

Pulse Width
:
1 ms min

Duty factor
:


Output Signal Levels
:
Voltage pulse ON:6.5V min OFF : 1 V max



Open Collector ON:1V max

Max.Operatiing Current
:
30mA

Max.Operating Voltage
:
40V DC (OPEN COLLECTOR)

Contact Bounce
:


Life
:


Signal Cable
:
Vinyl-insulated,4-conductor,shielded (core wire 0.5mm²,4 to 10mm in O.D)

Transmission Distance
:
1 Kilometer max.(using a CVVS cable 1.25 to 2.0mm²)

Power
:
12 to 24VDC ±10%

Current Drain
:
20mA max





Item
:
Reed switch

Type of output pulse
:
Contact-closure pulse

Number of pulses (per pointer rev.)
:
1 P

Pulse Width
:


Duty factor
:
40/60 to 60/40

Output Signal Levels
:


Max.Operatiing Current
:
60mA (200Ω protective resistor provided)

Max.Operating Voltage
:
125V AC,50V DC

Contact Bounce
:
0.5ms max

Life
:
5 x 10⁷ cycles off operating (with resistive load at 12V DC,10mA)

Signal Cable
:
Vinyl-insulated,4-conductor,shielded (core wire 0.5mm²,4 to 10mm in O.D)

Transmission Distance
:
1 Kilometer max.(using a CVVS cable 1.25 to 2.0mm²)

Power
:


Current Drain
:






Mechanical Register Pulse Output



Model
:
LS5576-2OOA

Nominal Size (mm)
:
40

MR Sensor



Pulse Units
:
1 L/P

Pulse Units at Max Flow Rate
:
3.8 Hz

Reed Switch



Output Freq
:
10 L/P

Pulse Units Output Freq
:
0.38 Hz

at max Flow Rate



Max Flow Rate (L/h)
:
14000